Mt Edwards Lithium Project Update
Released
Released
Announcement PDF
3 February 2017
Company Announcements
ASX Limited
MELP UPDATE
Drilling delay due to heavy rainstorms
Axis drill core assays received
MAIDEN RC DRILLING PROGRAM MT EDWARDS LITHIUM PROJECT
The Company advises that due to heavy rainfall in the immediate project area and
surrounds, the maiden RC drilling program at the Mt Edwards Lithium Project (MELP) has
been delayed. At this stage, crews have been stood down until next week when it’s
expected that the ground conditions will have improved sufficiently for the movement of
the heavy drilling fleet and auxiliary vehicles to commence drilling target areas.
AXIS DRILL CORE ANALYSIS
The Company announces that is has received assay results from SGS Oretest for the
historic diamond drill core MND1213 and MND1214 that was submitted for analysis for
lithium and an accompanying suite of LCT pegmatite elements (See Appendix 2 for full
results).
The holes were originally drilled to target nickel at the Axis Prospect, which is located
approximately 3.4km west of recently discovered lithium mineralisation at the Munda
prospect. The drill core contained significant widths of pegmatite, not dissimilar to the initial
observations made by other explorers of historic diamond drill core which led to significant
lithium discoveries (see ASX release 16th November 2016 for details).
While moderately anomalous in places, assay results have returned relatively low levels
of lithium, which has downgraded the Axis Prospect area. Although the location of the
granite source of the pegmatites of the MELP area is unknown, these results demonstrate
that Axis is possibly not at the optimal distance from the source to produce economic
concentrations of lithium. The Company will now focus its upcoming drilling programs at
Kingmaker, Atomic Three, Inco Boundary and Munda where it has already obtained highly
anomalous lithium results from surface rock chip sampling of exposed pegmatites.
The Company looks forward to updating shareholders further as it progresses the MELP.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Table 1. Tenement Schedule
Schedule of Mining and Exploration Tenements
Country
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
Australia
State/Region
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Mt Edwards Lithium Project
Tenement ID
M15/698
M15/75
M15/699
M15/87
M15/74
M15/101
M15/99
M15/653
M15/97
M15/96
M15/102
M15/100
M15/1271
E15/1505
E15/1507
E15/1562
Area Km2
4.2
5.7
3.4
3.6
9.3
9.6
9.8
10
6.8
8.4
9.3
9.6
4.8
2
15
16
Grant Date
22/12/1994
10/11/1984
23/12/1994
26/07/1984
10/11/1984
23/07/1984
23/07/1984
28/01/1993
23/07/1984
23/07/1984
4/01/1985
23/07/1984
2/07/2007
5/10/2016
Application
Application
Interest %
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
Competent Person Statement
The information in this announcement that relates to Exploration Results, Mineral Resources or Ore Reserves is
based on information compiled by Luke Marshall, who is a consultant to Apollo Phoenix Resources and Mt Edwards
Lithium, and a member of The Australasian Institute of Geoscientists. Mr Marshall has sufficient experience that is
relevant to the style of mineralisation and type of deposit under consideration and to the activity that he is
undertaking to qualify as a Competent Person as defined in the 2012 Edition of the “Australasian Code for
Reporting of Exploration Results, Mineral Resource and Ore Reserves”. Mr Marshall consents to the inclusion in the
report of the matters based on his information in the form and context in which it appears.
FURTHER INFORMATION CONTACT
Christopher J. Daws
Chief Executive Officer
Estrella Resources Limited
info@estrella.com.au
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
APPENDIX 1 JORC TABLE 1 - JORC CODE, 2012 EDITION – TABLE 1 MELP
Section 1 Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections.)
Criteria
JORC Code explanation
Commentary
Sampling
techniques
Nature and quality of sampling (e.g. cut channels,
MELP has been drilled by percussion, diamond drilling and RC drilling. Accurate drilling data
random chips, or specific specialised industry
exists for 317 drill holes for 31669.57 metres in the area. This does not include blast holes or
standard measurement tools appropriate to the
grade control holes from Ni and Au mining.
minerals under investigation, such as down hole
gamma sondes, or handheld XRF instruments,
The holes have been drilled on irregular spacing, as tight as 15m by 20m in areas of Ni and/or
Au mineralisation, and broadening to kilometre plus spacing in unmineralised areas.
etc.). These examples should not be taken as
limiting the broad meaning of sampling.
Diamond holes were selectively sampled through the visible pegmatite zones on a nominal 1m
sample length, adjusted to geological and domain boundaries. Sample lengths vary from 0.35m
to 4.2m.
Diamond core samples have been sampled by a half core cut samples of NQ diameter.
RC drill holes are not reported in this announcement.
Include reference to measures taken to ensure
sample
representivity
and
the
appropriate
calibration of any measurement tools or systems
Sample representivity for diamond core was ensured by the sampling of an average length of
1m of core, which was then cut in half.
RC sampling is not reported in this announcement.
used.
Aspects of the determination of mineralisation that
are material to the Public Report.
Sample lengths for diamond drilling range from 0.35 to 4.2 m and average approximately 1.0
m. RC samples are not being reported.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Mineralised intervals are determined by visual inspection and logging prior to any sampling.
Laboratory assays are then compared to the visual estimates and logging to determine if any
adjustments are required.
In cases where ‘industry standard’ work has been
done this would be relatively simple (e.g. ‘reverse
Mineralisation is identified as course grained pegmatite hosted in a mafic-ultramafic package.
Representative samples from diamond drilling were collected and sent to SGS Oretest
circulation drilling was used to obtain 1 m samples
laboratory in Kalgoorlie. Samples were send to Perth, crushed and pulverised in entirety, and
from which 3 kg was pulverised to produce a 30g
a 50g pulp taken for analysis.
charge for fire assay’). In other cases, more
explanation may be required, such as where there
Analysis was performed by 4 acid digest and a combination of ICP-MS and ICP-OES multi
element analysis techniques.
is coarse gold that has inherent sampling
problems. Unusual commodities or mineralisation
Minor Rb and Cs occur in the mineralisation.
types (e.g. submarine nodules) may warrant
disclosure of detailed information
Drilling
techniques
Drill type (e.g. core, reverse circulation, open-hole
hammer, rotary air blast, auger, Bangka, sonic,
The data used is comprised of diamond drilling samples (376).
Diamond drilling was NQ diameter core.
etc.) and details (e.g. core diameter, triple or
standard tube, depth of diamond tails, facesampling bit or other type, whether core is
oriented and if so, by what method, etc.).
Drill sample
recovery
Method of recording and assessing core and chip
sample recoveries and results assessed.
Measures taken to maximise sample recovery
Core recoveries were not recorded for this historic diamond core. No geotechnical logs were
found. Core recoveries are not recorded in the database for this core. Diamond core recoveries
were estimated to be at least 95%.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
and ensure representative nature of the samples.
Whether a relationship exists between sample
No relationship could be established between sample recovery and reported grade.
recovery and grade and whether sample bias may
have occurred due to preferential loss/gain of
fine/coarse material.
Logging
Whether core and chip samples have been
geologically and geotechnically logged to a level
of detail to support appropriate Mineral Resource
Detailed drill hole logs are available for the drilling.
Separate sample logging sheets were kept including samples numbers for duplicates,
standards and blanks taken for QA/QC purposes.
estimation, mining studies and metallurgical
The logging is of a detailed nature, and of sufficient detail to support the results.
studies.
Whether logging is qualitative or quantitative in
nature.
Core
(or
costean,
channel,
The total length of drill intersections used in this announcement is 553m.
etc.)
photography.
The total length and percentage of the relevant
intersections logged.
Subsampling
techniques
and sample
preparation
If core, whether cut or sawn and whether quarter,
half or all core taken.
Sample preparation is appropriate the diamond drilling as per industry standard practices for
If non-core, whether riffled, tube sampled, rotary
split, etc. and whether sampled wet or dry.
For all sample types, the nature, quality and
appropriateness
of
The core was halved by sawing before sampling
the
sample
preparation
managing diamond core
Quality control procedures included the inclusion of standard samples and blank samples into
the sampling stream for laboratory analysis. 19 QAQC samples have been analysed for this
announcement. No bias or major analytical errors have been found.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Host rock is felsic pegmatite. Samples of diamond core produce appropriate size samples to
technique.
Quality control procedures adopted for all sub-
be representative for the style of mineralisation and rock type encountered.
sampling stages to maximise representivity of
samples.
Measures taken to ensure that the sampling is
representative of the in-situ material collected,
including
for
instance
results
for
field
duplicate/second-half sampling.
Whether sample sizes are appropriate to the grain
size of the material being sampled.
Quality of
assay data
and
laboratory
tests
For geophysical tools, spectrometers, handheld XRF instruments, etc.,
Quality control procedures included the inclusion of standard samples
the parameters used in determining the analysis including instrument
and blank samples into the sampling stream for laboratory analysis.
make and model, reading times, calibrations factors applied and their
One standard or blank was inserted into the sample stream every 20
derivation, etc.
Nature of quality control procedures adopted (e.g. standards, blanks,
duplicates, external laboratory checks) and whether acceptable levels
of accuracy (i.e. lack of bias) and precision have been established.
samples. These were offset through the sampling stream and placed
in areas of interest
Overall, standards used reported values within 2 standard deviations
of the expected values with a few exceptions.
No geophysical methods or hand-held XRF units have been used for
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
this announcement
Verification
of sampling
and
assaying
The verification of significant intersections by either independent or
alternative company personnel.
Intersections reported have been checked back to original logs and
assay data
The use of twinned holes.
No twin holes were drilled
Documentation of primary data, data entry procedures, data
Drill hole data were sourced from digital sources and original hard-copy
verification, data storage (physical and electronic) protocols.
sampling and assay records, and imported into a central electronic
database. Datashed software was used to validate and manage the
data.
Location of
data points
Discuss any adjustment to assay data.
No adjustments were made to the assay data
Accuracy and quality of surveys used to locate drill holes (collar and
Field checking confirmed the presence of the drillhole collars on the
down-hole surveys), trenches, mine workings and other locations used
in Mineral Resource estimation.
Specification of the grid system used.
ground
No other survey confirmation has taken place
Original surveying was undertaken in MGA94 zone 51 by handheld
GPS
Data spacing
and
distribution
Quality and adequacy of topographic control.
Topographic control is considered more than adequate for the current
announcement
Data spacing for reporting of Exploration Results.
N/A, these are two randomly spaced exploration holes
Whether the data spacing and distribution is sufficient to establish the
N/A’ no Mineral Resource or Ore Reserve is being reported
degree of geological and grade continuity appropriate for the Mineral
Resource and Ore Reserve estimation procedure(s) and classifications
applied.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Orientation
of data in
relation to
geological
structure
Whether sample compositing has been applied
No compositing has been applied. Intercepts are quoted as length
weighted intervals
Whether the orientation of sampling achieves unbiased sampling of
The drill line and drill hole orientation is oriented as close as practicable
possible structures and the extent to which this is known, considering
to perpendicular to the orientation of the general mineralised
the deposit type.
orientation
If the relationship between the drilling orientation and the orientation of
key mineralised structures is considered to have introduced a sampling
Most the drilling intersects the mineralisation at close to 90 degrees
ensuring intersections are representative of true widths.
bias, this should be assessed and reported if material.
Sample
security
The measures taken to ensure sample security.
Sample security was ensured as the core was cut and sampled in the
St Ives core yard, which is a secure compound.
A thorough process of logging, recording, sample storage and dispatch
to labs was followed
Audits or
reviews
The results of any audits or reviews of sampling techniques and data.
Sample data reviews have included an inspection and investigation of
all available paper and digital geological logs to ensure correct entry
into the drill hole database.
Visualisation of drilling data in three-dimensional software (Micromine
and Surpac) and QA/QC sampling review using Maxwell Geoservices
QAQCR Software was undertaken. Although these reviews are not
definitive, they provide confidence in the general reliability of the data.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Section 2 Reporting of Exploration Results
(Criteria listed in the preceding section also apply to this section.)
Criteria
JORC Code explanation
Commentary
Mineral
tenement and
land tenure
status
Type, reference name/number, location and ownership including
Estrella Resources Limited holds a 75% interest the lithium metal
agreements or material issues with third parties such as joint ventures,
partnerships, overriding royalties, native title interests, historical sites,
rights to the project.
There are no known impediments to operate in the area.
wilderness or national park and environmental settings.
The security of the tenure held at the time of reporting along with any
known impediments to obtaining a licence to operate in the area.
Exploration
done by other
parties
Acknowledgment and appraisal of exploration by other parties.
Exploration
has
been
undertaken
by previous
holders,
but
predominantly Western Mining Corporation (WMC) during the 1980s
and Titan Resources from 2001. Consolidated Minerals took over
Titan in 2006. No mining for Li has been undertaken on the project.
Geology
Deposit type, geological setting and style of mineralisation.
The geology at MELP consists of a mafic-ultramafic belt bound to the
west by metasediments and to the east by granites
The mineralisation at MELP consists of structurally controlled
pegmatite bodies located in a mafic-ultramafic package, at some
distance from their parent granite. The parent granite is yet to be
identified at the MELP.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
The geometry and size of the pegmatites is yet to be determined
Depth of complete oxidation varies from 10 to 80 metres below the
natural surface but is typically around 40 metres. Pegmatites tend to
be relatively fresh at surface compared to their host lithologies
Drill hole
Information
A summary of all information material to the understanding of the
exploration results including a tabulation of the following information
See Appendix 2- Drilling Information
No information is excluded
for all Material drill holes:
o
easting and northing of the drill hole collar
o
elevation or RL (Reduced Level – elevation above
sea level in metres) of the drill hole collar
o
dip and azimuth of the hole
o
down hole length and interception depth
o
hole length.
If the exclusion of this information is justified on the basis that the
information is not Material and this exclusion does not detract from the
understanding of the report, the Competent Person should clearly
explain why this is the case.
Data
aggregation
methods
In reporting Exploration Results, weighting averaging techniques,
Drill hole summary results are included in this release. The results
maximum and/or minimum grade truncations (e.g. cutting of high
reported include all intersections included in the announcement
grades) and cut-off grades are usually Material and should be stated.
A nominal cut-off of 250ppm Li was used to define the drill
Where aggregate intercepts incorporate short lengths of high grade
intersections composites. A 5m maximum internal dilution was used.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
results and longer lengths of low grade results, the procedure used for
Tables the report contains all weighted composites included in the
such aggregation should be stated and some typical examples of such
announcement. Higher grade intersections within the composites are
aggregations should be shown in detail.
included in the table.
The assumptions used for any reporting of metal equivalent values
No metal equivalents are used in this announcement
should be clearly stated.
Relationship
between
mineralisation
widths and
intercept
lengths
These relationships are particularly important in the reporting of
Exploration Results.
If the geometry of the mineralisation with respect to the drill hole angle
is known, its nature should be reported.
The drill line and drill hole orientation is oriented as close to 90 degrees
to the orientation of the anticipated mineralised orientation as
practicable
The drilling intersects the stratigraphy at approximately 80 degrees.
If it is not known and only the down hole lengths are reported, there
should be a clear statement to this effect (e.g. ‘down hole length, true
width not known’).
Diagrams
Appropriate maps and sections (with scales) and tabulations of
Appropriate maps and tables are included in the body of the report.
intercepts should be included for any significant discovery being
reported. These should include, but not be limited to a plan view of drill
hole collar locations and appropriate sectional views.
Balanced
reporting
Where comprehensive reporting of all Exploration Results is not
All drill intercepts are tabulated in the body of the announcement.
practicable, representative reporting of both low and high grades
All drill hole collars are tabulated in the body of the announcement
and/or widths should be practiced to avoid misleading reporting of
Exploration Results.
Other
substantive
Other exploration data, if meaningful and material, should be reported
Mineral resources were estimated from drill hole assay data, with
including (but not limited to): geological observations; geophysical
geological logging used to aid interpretation of mineralised contact
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
exploration
data
survey results; geochemical survey results; bulk samples – size and
method of treatment; metallurgical test results; bulk density,
groundwater,
geotechnical
and
rock
characteristics;
positions.
Geological observations are included in the report. All core drilled at
potential
MELP is available for review and is stored at the St Ives Coreyard in
deleterious or contaminating substances.
Kambalda.
Metallurgical test work is out of the scope of this report.
Multi-element assay suites have been analysed and nothing has been
identified as a potentially deleterious element.
Further work
The nature and scale of planned further work (e.g. tests for lateral
extensions or depth extensions or large-scale step-out drilling).
Diagrams clearly highlighting the areas of possible extensions,
including the main geological interpretations and future drilling areas,
provided this information is not commercially sensitive.
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Bulk density measurements have not been taken
No further work is planned at Axis at this stage.
Drill spacing is currently considered adequate to undertake limited
high level economic evaluations on the project. Infill drilling would be
required if more detailed feasibility studies were to be undertaken.
APPENDIX 2 – Detailed Drilling Laboratory Assay Results and Collar Details.
Table 2. Drillhole Location Details and Pegmatite Intersections
Hole_ID
Prospect
MGA_East
MGA_North
RL
Dip
Azimuth
From
To
Width
MND1314
Axis
357065
6513876
347
-88
041
121.60
182.00
60.40
MND1314
Axis
198.25
207.8
9.55
MND1314
Axis
208.65
210.35
1.7
MND1314
Axis
211.8
213.9
2.1
MND1314
Axis
216.8
225.85
9.05
MND1314
Axis
228.3
229.3
1.0
MND1314
Axis
236
236.5
0.5
MND1314
Axis
246.6
248.2
1.6
MND1314
Axis
248.95
258.65
9.7
MND1314
Axis
275.35
288
12.65
MND1312
Axis
88.65
102.35
13.69
MND1312
Axis
106.5
120.75
14.25
MND1312
Axis
128.00
159.95
31.95
MND1312
Axis
176.6
179
2.4
MND1312
Axis
179.9
182.8
2.9
MND1312
Axis
195.35
196.1
0.75
MND1312
Axis
196.7
198.6
1.9
MND1312
Axis
201.40
229.50
28.10
231.40
265.00
33.60
6.6
17.5
10.9
MND1312
Axis
WID1045
Larkinville
356932
6513441
357560
6520577
344
355
-87
139
-45
204
Table 3. Detailed Assay Reslts
Hole_ID
mFrom
mTo
Li_ppm
Be_ppm
Cs_ppm
Ga_ppm
Nb_ppm
Rb_ppm
Sn_ppm
Ta_ppm
Tl_ppm
MND1312
88.65
89
20
2.4
0.8
18
MND1312
89
90
15
2.3
1.9
25
15
6.8
<100
<10
<0.25
25
210
<100
<10
1.2
MND1312
90
91
15
2.4
3.2
27
40
385
<100
<10
2.3
MND1312
91
92
10
2.2
6.6
24
15
512
<100
<10
3.4
MND1312
92
93
20
MND1312
93
94
20
2.4
7.9
29
30
547
<100
<10
3.6
2.3
5.2
26
40
303
<100
<10
2.1
MND1312
94
95
20
2.4
5.5
25
45
343
<100
<10
2.5
MND1312
95
MND1312
96
96
30
2.3
6.7
27
55
527
<100
<10
3.8
97
30
2.6
5.9
28
40
345
<100
<10
2.5
MND1312
97
98
25
3
4.3
26
60
306
<100
<10
2.2
MND1312
98
99
25
2.6
5.6
28
75
364
<100
<10
2.5
MND1312
99
100
25
2.3
4.6
25
40
366
<100
<10
2.6
MND1312
100
101
25
2.6
6.1
27
30
523
<100
<10
3.8
MND1312
101
102
15
2.9
3.4
31
45
349
<100
<10
2.4
MND1312
102
102.35
15
4.7
1.6
32
55
59.9
<100
<10
0.5
MND1312
102.35
103
25
1.5
2.9
11
15
23.1
<100
<10
0.5
MND1312
103
104
<10
2
1.2
8
<10
2.3
<100
<10
0.3
MND1312
104
105
<10
1.4
0.7
10
<10
5
<100
<10
0.3
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Hole_ID
mFrom
mTo
Li_ppm
Be_ppm
Cs_ppm
Ga_ppm
Nb_ppm
Rb_ppm
Sn_ppm
Ta_ppm
Tl_ppm
MND1312
105
106
<10
1.2
0.7
9
<10
3.3
<100
<10
0.3
MND1312
106
106.5
60
1.6
12.8
12
<10
109
<100
<10
1.1
MND1312
106.5
107
210
4.1
17
20
30
238
<100
<10
1.8
MND1312
107
108
20
3.6
2.1
25
20
97.6
<100
<10
0.7
MND1312
108
109
20
3.4
1.1
30
45
60.4
<100
<10
0.4
MND1312
109
110
15
3.1
3.4
35
70
432
<100
<10
3
MND1312
110
111
20
3.3
2.7
29
60
326
<100
<10
2.2
MND1312
111
112
25
3.3
3.2
31
50
297
<100
<10
2.1
MND1312
112
113
20
2.4
3.8
27
40
362
<100
<10
2.5
MND1312
113
114
25
2.4
3.7
29
40
308
<100
<10
2.2
MND1312
114
115
20
2
3.2
27
35
359
<100
<10
2.5
MND1312
115
116
15
3
3.3
30
50
240
<100
<10
1.6
MND1312
116
117
15
2.8
2.9
26
30
190
<100
<10
1.4
MND1312
117
118
10
3.2
2.4
29
40
259
<100
<10
1.8
MND1312
118
119
15
3.1
1.2
28
40
64.5
<100
<10
0.4
MND1312
119
120
<10
3.3
0.7
30
45
30
<100
<10
<0.25
MND1312
120
120.75
20
3.2
1.8
30
45
106
<100
<10
0.6
MND1312
120.75
122
345
4.7
93.4
14
15
605
<100
<10
5.1
MND1312
122
123
210
3.5
71.1
12
15
408
<100
<10
3.5
MND1312
123
124
95
4.9
5.7
15
20
30.4
<100
<10
0.6
MND1312
124
124.45
340
4.9
21.4
21
25
136
<100
<10
1.2
MND1312
124.45
124.85
110
8
11
35
50
77.1
<100
<10
0.6
MND1312
124.85
126
215
5.4
5.8
17
15
33.1
<100
<10
0.4
MND1312
126
127
250
4.6
74.6
16
15
580
<100
<10
4.2
MND1312
127
128
215
3.9
86.9
16
10
718
<100
<10
5.6
MND1312
128
129
30
4.4
6.1
29
35
117
<100
<10
0.9
MND1312
129
130
20
2.1
6
27
35
424
<100
<10
3
MND1312
130
131
20
2.2
5.3
28
40
313
<100
<10
2.2
MND1312
131
132
30
2
3.5
28
25
193
<100
<10
1.5
MND1312
132
133
25
2.9
5.1
27
50
340
<100
<10
2.4
MND1312
133
134
15
2.4
6.7
27
30
427
<100
<10
3.1
MND1312
134
135
20
2.1
5.4
25
30
398
<100
<10
2.8
MND1312
135
136
20
2.1
4.6
25
35
282
<100
<10
2.1
MND1312
136
137
35
2.8
6.6
27
50
334
<100
<10
2.3
MND1312
137
138
40
2.6
7.1
27
45
356
<100
<10
2.4
MND1312
138
139
40
2.3
6.9
19
25
311
<100
<10
2.1
MND1312
139
140
30
2.2
7.5
28
40
392
<100
<10
2.3
MND1312
140
141
45
3.1
7.8
29
55
503
<100
<10
2.6
MND1312
141
142
40
2.1
8.1
27
45
441
<100
<10
2.8
MND1312
142
143
50
2.7
4.3
28
40
266
<100
<10
1.8
MND1312
143
144
50
1.6
7.1
27
50
487
<100
<10
3.1
MND1312
144
145
35
2.1
6.8
26
30
419
<100
<10
2.9
MND1312
145
146
50
2.5
5.9
26
25
239
<100
<10
1.6
MND1312
146
147
40
1.2
7.7
24
20
538
<100
<10
3.5
MND1312
147
148
30
2.3
5.7
25
20
410
<100
<10
2.5
Office Address Level 11, 216 St Georges Terrace, PERTH WA 6000 Postal Address GPO Box 2517, PERTH WA 6831 Phone +61 8 9481 0389
Email info@estrellaresources.com.au
Hole_ID
mFrom
mTo
Li_ppm
Be_ppm
Cs_ppm
Ga_ppm
Nb_ppm
Rb_ppm
Sn_ppm
Ta_ppm
Tl_ppm
MND1312
148
149
30
1.7
4.9
25
25
324
<100
<10
2.2
MND1312
149
150
25
2.1
6.3
27
30
274
<100
<10
1.9
MND1312
150
151
35
1.4
2.3
10
10
106
<100
<10
0.8
MND1312
151
152
30
2.6
7.2
28
25
392
<100
<10
2.5
MND1312
152
153
40
2.2
8.4
25
30
485
<100
<10
3.2
MND1312
153
154
35
1.9
8.8
28
20
604
<100
<10
3.9
MND1312
154
155
55
2
6.7
25
25
474
<100
<10
2.7
MND1312
155
156
40
3
10
28
50
505
<100
<10
2.6
MND1312
156
157
30
3.3
5.8
32
55
244
<100
<10
1.4
MND1312
157
158
20
2.4
5.7
28
35
174
<100
<10
1.2
MND1312
158
159
15
2
4.6
27
30
275
<100
<10
1.6
MND1312
159
159.95
10
3.3
2.4
33
40
186
<100
<10
1.1
MND1312
159.95
161
395
5.8
130
18
15
646
<100
<10
5.6
MND1312
161
162
200
4.9
58.3
15
25
313
<100
<10
2.9
MND1312
162
163
70
2.5
29.8
9
<10
152
<100
<10
1.8
MND1312
163
164
<10
1.4
2.1
8
<10
5.5
<100
<10
0.6
MND1312
164
165
10
2.2
1
9
<10
2.7
<100
<10
0.3
MND1312
165
166
<10
2.2
1.1
8
<10
2.9
<100
<10
0.5
MND1312
166
167
<10
3
0.9
8
<10
2.1
<100
Share your feedback
Discover